A.KRÜSS Optronic Brochure Density Meters
A.KRÜSS Optronic Brochure Density Meters, English PDF document.
View resource →
Series: DS7000
Model: DS7700-M / DS7800-M
DS7700-M/DS7800-M use manual syringe filling for density and concentration measurements of low- to high-viscosity samples.
Application / measured object:
Density, relative-density and concentration measurements for suitable liquids and emulsions; sample identification, quality and purity checks.
For manual-fill models, approximately 0.9 ml sample is injected into the oscillating U-tube by syringe, suiting laboratories with fewer samples or a priority on flexible sample changes.
| Model | Sample supply | Density accuracy | Resolution |
|---|---|---|---|
| DS7700-M | Manual syringe | ±0.001 g/cm³ | 0.001 g/cm³ |
| DS7800-M | Manual syringe | ±0.0001 g/cm³ | 0.0001 g/cm³ |

| Item | Specification |
|---|---|
| Measurement range | 0–3 g/cm³ |
| Temperature-control range | 10–40 °C |
| Temperature-control accuracy | ±0.01 °C |
| Measurement period | 3 s after temperature equalisation |
| Minimum measuring-cell sample volume | 0.9 ml |
| Pressure range (relative) | 0–9 bar |
| Temperature-measurement accuracy | ±0.02 °C |
| Temperature-measurement resolution | 0.01 °C |
| Scales | Density, relative density, Brix, alcohol (vol.%), sulphuric acid (mass%), unlimited user-defined scales |
| Method capacity | More than 10,000 |
| Adjustment | Automatic, menu-guided; air-pressure sensor and temperature-controlled calibration media |
| Sample-contact materials | Borosilicate glass, PTFE |
| Additional functions | Audit trail, user management, measured-value stabilisation, air-pressure display |
| Operation and display | 7.0-inch capacitive touchscreen, 800 × 480 pixels; keyboard, mouse, barcode scanner |
| Physical interfaces | 1 × USB;1 × RS-232;1 × Ethernet |
| System integration | LIMS |
| Dimensions (W × H × D) | 220 × 220 × 430 mm |
| Instrument weight | 5.3 kg |
| Operating voltage / frequency | 100–240 V; 47–63 Hz |
| Measuring / maximum power | 25 W / 120 W |
Density accuracy is specified at 20 °C, 1013 hPa and 50% relative humidity. 0.9 ml is the measuring-cell minimum; total sample requirements also depend on tubing and sample-supply configuration.
For low-throughput density, relative-density and concentration measurement in pharmaceutical, chemical, petrochemical, food and beverage laboratories.
Certified isooctane, n-nonane, ultrapure-water and dichlorotoluene density standards are available separately. Use the temperature and reference density stated on the relevant certificate.
Pump and autosampler options can be chosen for the workflow. AS80 provides 18 or 36 positions; AS90 provides 53 or 89. Replacement consumables include TPE pump tubing, PTFE connectors and adaptors. Protective cover, CBM910 printer and print consumables are available separately.
The models differ mainly in density accuracy and resolution. Choose manual filling for low sample counts and flexible changes, then match accuracy to quality-system requirements.
Product selection and application support
Tell us about your sample, application and target parameters. The Labsun team will help you select a suitable instrument or solution.