Dewar Selection: Separate Body, Casing and Lid Temperature Limits
The inner vessel, casing, cushioning and closure may have different temperature limits. Equal capacity does not establish identical cryogenic holding performance.
View resource →
Series: Cylindrical Dewar vessels
Model: 00 C to S 22 C; G-C variants
The cylindrical 00 C–S 22 C glass Dewars provide approximately 100–8000 ml for small-sample cooling, temporary cryogen storage and insulated containment.
Application / measured object:
Laboratory small-sample cooling, storage of liquid nitrogen, dry ice and other cooling media, and insulated containment.
The cylindrical 00 C–S 22 C glass Dewars provide approximately 100–8000 ml for small-sample cooling, temporary cryogen storage and insulated containment. C and G-C differ in the side-handle configuration of the protective casing; capacities, dimensions, holding times and order numbers are listed below.



| Type | max. content approx. [ml] | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] | Weight approx. [kg] | Service life LN2 approx. [h] | Evaporation rate LN2 approx. [L/d] | Type C Item no: | Type G-C Item no: |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 C | 100 | 40 | 56 | 63 | 90 | 135 | 0.2 | 7 | 0.3 | 1021 | – |
| 0 C | 200 | 40 | 56 | 63 | 170 | 215 | 0.3 | 21 | 0.2 | 1022 | 1061 |
| 1 C | 300 | 47 | 60 | 72 | 190 | 240 | 0.3 | 31 | 0.2 | 1023 | 1062 |
| 2 C | 450 | 47 | 60 | 72 | 270 | 310 | 0.5 | 46 | 0.25 | 1024 | 1063 |
| 3 C | 500 | 57 | 70 | 81 | 210 | 260 | 0.5 | 30 | 0.35 | 1025 | 1064 |
| 4 C | 750 | 57 | 70 | 81 | 310 | 370 | 0.8 | 59 | 0.3 | 1026 | 1065 |
| 5 C | 1250 | 57 | 70 | 81 | 500 | 550 | 1.3 | 118 | 0.25 | 1027 | – |
| 6 C | 800 | 67 | 80 | 90 | 240 | 295 | 0.6 | 54 | 0.35 | 1028 | 1066 |
| 7 C | 1200 | 67 | 80 | 90 | 350 | 395 | 0.8 | 98 | 0.3 | 1029 | 1067 |
| 8 C | 1700 | 67 | 80 | 90 | 500 | 560 | 1.1 | 136 | 0.3 | 10210 | – |
| 9 C | 1000 | 77 | 95 | 105 | 235 | 290 | 0.7 | 60 | 0.35 | 10211 | 1068 |
| 10 C | 1500 | 77 | 95 | 105 | 345 | 395 | 1.1 | 80 | 0.4 | 10212 | 1069 |
| 11 C | 2100 | 77 | 95 | 105 | 500 | 550 | 1.8 | 130 | 0.4 | 10213 | – |
| 12 C | 1500 | 90 | 115 | 124 | 245 | 300 | 1.1 | 53 | 0.5 | 10214 | 10610 |
| 13 C | 2000 | 90 | 115 | 124 | 340 | 390 | 1.4 | 90 | 0.5 | 10215 | 10611 |
| 14 C | 3200 | 90 | 115 | 124 | 600 | 665 | 2.5 | 193 | 0.45 | 10216 | – |
| 15 C | 1500 | 100 | 120 | 130 | 240 | 300 | 1.2 | 49 | 0.7 | 10217 | 10612 |
| 16 C | 2000 | 100 | 120 | 130 | 290 | 345 | 1.4 | 77 | 0.6 | 10218 | 10613 |
| 17 C | 4000 | 100 | 120 | 130 | 600 | 660 | 2.9 | 156 | 0.65 | 10219 | – |
| 18 C | 2500 | 110 | 130 | 140 | 290 | 345 | 1.7 | 74 | 0.7 | 10220 | 10614 |
| 19 C | 5000 | 110 | 130 | 140 | 600 | 660 | 3.2 | 207 | 0.6 | 10221 | – |
| 20 C | 3000 | 138 | 160 | 165 | 230 | 280 | 1.4 | 55 | 1.2 | 10222 | 10615 |
| S 21C | 4000 | 138 | 160 | 165 | 310 | 375 | 2.4 | 92 | 1.0 | 10223 | 10616 |
| S 22 C | 8000 | 138 | 160 | 165 | 600 | 660 | 4.6 | 220 | 0.9 | 10224 | 10617 |
| Type | Capacity approx. (ml) | A (mm) | B (mm) | D (mm) | Order number |
|---|---|---|---|---|---|
| 00 A | 100 | 40 | 56 | 90 | 1011 |
| 0 A | 200 | 40 | 56 | 170 | 1012 |
| 1 A | 300 | 47 | 60 | 190 | 1013 |
| 2 A | 450 | 47 | 60 | 270 | 1014 |
| 3 A | 500 | 57 | 70 | 210 | 1015 |
| 4 A | 750 | 57 | 70 | 310 | 1016 |
| 5 A | 1250 | 57 | 70 | 500 | 1017 |
| 6 A | 800 | 67 | 80 | 240 | 1018 |
| 7 A | 1200 | 67 | 80 | 350 | 1019 |
| 8 A | 1700 | 67 | 80 | 500 | 10110 |
| 9 A | 1000 | 77 | 95 | 235 | 10111 |
| 10 A | 1500 | 77 | 95 | 345 | 10112 |
| 11 A | 2100 | 77 | 95 | 500 | 10113 |
| 12 A | 1500 | 90 | 115 | 245 | 10114 |
| 13 A | 2000 | 90 | 115 | 340 | 10115 |
| 14 A | 3200 | 90 | 115 | 600 | 10116 |
| 15 A | 1500 | 100 | 120 | 240 | 10117 |
| 16 A | 2000 | 100 | 120 | 290 | 10118 |
| 17 A | 4000 | 100 | 120 | 600 | 10119 |
| 18 A | 2500 | 110 | 130 | 290 | 10120 |
| 19 A | 5000 | 110 | 130 | 600 | 10121 |
| 20 A | 3000 | 138 | 160 | 230 | 10122 |
| S 21 A | 4000 | 138 | 160 | 310 | 10123 |
| S 22 A | 8000 | 138 | 160 | 600 | 10124 |
| Compatible type | Capacity approx. (ml) | Order number |
|---|---|---|
| 00 | 100 | 1721 |
| 0 | 200 | 1722 |
| 1 | 300 | 1723 |
| 2 | 450 | 1724 |
| 3 | 500 | 1725 |
| 4 | 750 | 1726 |
| 5 | 1250 | 1727 |
| 6 | 800 | 1728 |
| 7 | 1200 | 1729 |
| 8 | 1700 | 17210 |
| 9 | 1000 | 17211 |
| 10 | 1500 | 17212 |
| 11 | 2100 | 17213 |
| 12 | 1500 | 17214 |
| 13 | 2000 | 17215 |
| 14 | 3200 | 17216 |
| 15 | 1500 | 17217 |
| 16 | 2000 | 17218 |
| 17 | 4000 | 17219 |
| 18 | 2500 | 17220 |
| 19 | 5000 | 17221 |
| 20 | 3000 | 17222 |
| S 21 | 4000 | 17223 |
| S 22 | 8000 | 17224 |
Laboratory small-sample cooling, storage of liquid nitrogen, dry ice and other cooling media, and insulated containment.
Select capacity, opening and depth, then check C/G-C casing, LN₂ holding time and evaporation rate. Match replacement A inserts by type; stoppers have separate order numbers.
Product selection and application support
Tell us about your sample, application and target parameters. The Labsun team will help you select a suitable instrument or solution.